
MSA plug-in for Gatan DigitalMicrograph (GMS2.x 64 bit)
--------------------------------------------------------------------------------

Version 2.2
Dec 2017

--------------------------------------------------------------------------------
Contact

General enquiries on the MSA for DigitalMicropraph should be sent to: 
HREM Research Inc.
14-48 Matsukazedai
Higashimatsuyama 
Saitama 355-0055
Japan

email: mailto:support@hremresearch.com
Website: http://www.hremresearch.com /

Enquiries on MSA of a technical nature should be directed to: 
Dr. Masashi Watanabe
Department of Materials Science and Engineering/
Center for Advanced Materials and Nanotechnology
Lehigh University, Bethlehem, PA18015, USA

email: masashi.watanabe@lehigh.edu
Website: http://www.lehigh.edu/~maw3/index.html /

--------------------------------------------------------------------------------
Files
	- DMMSA64.gtk: core executable file
	- DMMSA64.dll: core executable file
	- DMMSAUtils64.dll: core executable file
	- MSAforDM_manual.pdf: help file
	- MSAforDM_QuickReference.pdf: help file
	- readme64.txt: this file

--------------------------------------------------------------------------------
Installation
	Installation is straightforward. Just copy the files to following folder.
	Go to \Gatan\Plugins folder: DMMSA.gtk, DMMSA.dll and DMMSAUtils.dll
	Go to \Gatan\Help folder: MSAforDM_manual.pdf, MSAforDM_QuickReference.pdf
	
[NOTE] These Gatan folders may be found at two places, namely in "Program files" and/or "ProgramData" 
of Windows 7.  Since the Program files folder is no longer accessible to regular users, Gatan 
recommends to use the latter ProgramData folder to install the plug-in and help files. 

[NOTE] IPU plug-in should be also installed to run this plug-in.
--------------------------------------------------------------------------------
Release Notes
Version 2.2   Update for Local PCA
Version 2.1   DLL optimization for GMS 2.x by using INTEL C++ Compiler
Version 2.0.1 Windows 8 supported by a 64bit version
Version 2.0   New features: Spectrally and Spatially Local PCA
Version 1.6   Stacked display component and adjusted to GMS 2.3 (Jan./28/'14)
Version 1.5   Modified tag structure (July/10/'12)	
Version 1.4   Modified dialog formats (Oct./11/'11)	
Version 1.3   Adjusted to GMS 2.x and added Tags in resultant files processed by Bin SI, Spatial Sub SI, Spectral Sub SI and Weighted PCA (Sep./18/'11)
Version 1.2   Added an import option for Bruker system in XED-SI import (Dec./14/'09) 
Version 1.1   Minor bug fix (June/9/'09) 
Version 1.0   First official release version (Oct./30/'08) 
